SITC of AHUs with DX Units HVAC Electrical Civil Works in OTs 1 2 3 of Dept of Plastic Reconstructive Surgery at NIMS Hospital Hyderabad

Ai Generated Article, July 24, 2025July 24, 2025

Bill of Quantity Items Print Preview

Current Tender Details

Tender ID613349Enquiry/IFB/Tender Notice Number14/27/EE/2025-26
  Name of WorkSITC of AHUs with DX Units HVAC Electrical Civil Works in OTs 1 2 3 of Dept of Plastic Reconstructive Surgery at NIMS Hospital Hyderabad  Tender Category  Works
Tender TypeOPEN – NCBEstimated Contract Value5879983
Bid Submission Closing Date04/08/2025 04:00 PMTender Evaluation TypePercentage

Back                Print

BOQ Item Details

S.NoSubwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
1BOQWall and Celing Accostic Insulation for AHU Room1050.00Sft158.00165900.00
Wall and Celing Accostic Insulation for AHU Room for Sound Proofing. 20ft length x 12ft width x 12ft height
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
    2    BOQProviding and constructing AHU enclosure (7?m ×?4?m) including PCC base with Shabad stone flooring    1.00    Lot    113702.00    113702.00
Providing and constructing AHU enclosure (7?m ×?4?m) including PCC base with Shabad stone flooring, 230 mm thick front brick wall with plastering, and pre-coated GI sheet roofing over MS structural framework, complete with all materials, labour, fabrication, painting, anchoring, and finishing as per site conditions and Engineer-in-Charge instructions.Detailed work to execute is in tender document
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
  3  BOQ(SITC) of MS structural platform using 100×50×5 mm ISMC channels  6000.00  kgs  102.00  612000.00
?Supply, Installation, Testing, and Commissioning (SITC) of MS structural platform using 100×50×5 mm ISMC channels conforming to IS:2062 grade, complete with cutting, welding, bolting, anchoring, strengthening, base plates, and supports, including necessary civil foundation works with PCC pedestals and cementitious grouting, fixing of wall clamping arrangements with chemical/anchor bolts, application of one coat red oxide primer and two coats of synthetic enamel paint, waterproofing treatment at column base and wall interfaces, erection at site above 5.0 meters height

Subwork Name                                   Specification Number                        Quantity          UOM                   Rate(INR)      Amount(INR)

using scaffolding/lifting equipment, and complete in all respects as per drawings and specifications, including all labour, tools, safety PPEs, testing, T&P, and supervision, but excluding contractor?s

overheads and profit.?for AHU 1,2,3

 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
  4  BOQwaterproof PVC laminated ceiling tiles of size 600×600 mm  2500.00  sft  135.00  337500.00
Supply and installation of factory-manufactured branded waterproof PVC laminated ceiling tiles of size 600×600 mm, 6?8 mm thick, conforming to cleanroom and healthcare-grade standards, laid on exposed GI T-grid system (24 mm), including GI main runners, cross tees, perimeter channels, suspension system with GI wire hangers, adjustable clips, anchors, rawl plugs, and necessary accessories; installation to be carried out in true level using laser alignment, with all cutting, finishing, cleaning, and disposal of debris; tiles shall be anti-fungal, anti-bacterial, fire-retardant, washable, and VOC-free, suitable for Operation Theatre area above the operation table, complying with infection control and hospital hygiene standards, complete as per manufacturer’s specifications and as directed by Engineer-in-Charge.at lobby near Table 1,2 & 3 area.
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
5BOQDismantling of existing false ceiling2500.00sft14.7536875.00
Dismantling of existing false ceiling including careful removal of old ceiling tiles, GI grid system, hangers, and supports; clearing and disposal of debris from site as per instructions of Engineer-in- Charge, ensuring no damage to existing civil finishes, and complete site clearance with all labour, tools, and safety precautions.
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
6BOQDismantling of existing AHU3.00No27540.0082620.00
Dismantling of existing AHU units, electrical panels, copper refrigerant piping (with insulation), and outdoor units (ODUs), including disconnection, gas evacuation (if required), removal of supports using gas cutters/welding wherever necessary, safe handling, site clearance, and buy-back of all dismantled material/scrap by the contractor, with all dismantled items to be taken out through proper gate pass after due certification by the Engineer-in-Charge and Administration, including all labour, tools, equipment, transportation, and compliance with site safety protocols.
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
7BOQdrain pipe with CPVC pipes35.00Rmt555.0019425.00
Supply, installation, testing and commissioning of the drain pipe with CPVC pipes with all accessories and insulation with 6mm thick closed cell nitrile rubber of the following sizes,with all required accessoriesMakes : Astral / Ashirvad or equivalent approved by the department
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
8BOQ4 Sqmm 2 Core XLPE100.00Rmt160.0016000.00

Subwork Name                                   Specification Number                        Quantity          UOM                   Rate(INR)      Amount(INR)

Supply of 4 Sqmm 2 Core XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part- I)

 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
9BOQ6 Sqmm 4 Core XLPE100.00Rmt230.0023000.00
Supply of 6 Sqmm 4 Core XLPE insulated, 1100V grade armoured alluminium cable with ISI mark as per specification confirming to IS:7098 (Part – I) Makes : Torrent / Unicab
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
10BOQcontrol panel3.00No20500.0061500.00
Supply and Transportation of control panel for three phase submersible motors above 7.5 HP to 12.5 HP @ 415V 50Hz operating fitted with supply and fixing of Direct – on – Line LTLK(L&T) /BCH/ SIEMENS / CROMPTON make,0-500V Volt meter and 0-30A Ammeter,Indication lamps, selector switches, CTS, 32ATP MCB, Single phase preventor,suitable contactor to with stand low voltage pick up and high voltage resistant, with ISI marked capacitors assembled with ISI mark contactors and fitted with Legrand make ISI mark MCBetc.,complete.1 No 20500.00
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
11BOQnon porous doble layer canvas6.00No1895.0011370.00
Supply and fixing of fire retardant, non porous doble layer canvas of required size with GI frame, Gasket Nut bolts for air cooling plants /AHU’s / FCU’s etc., complete with marking connections etc., as required all as per approved by Engineer-In-Charge.1 No 1895.00
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
12BOQReturn Air Temperature & RH Sensor3.00No17000.0051000.00
Return Air Temperature & RH Sensor: Supply, Installation, Testing & Commissioning of Duct type Return Air Temperature & RH sensor with all the mounting accessories included. The sensor shall be Pt1000 RTD type for temperature measurement with 0 to 10V / 4-20mA transmitters. The temperature measurement range shall be 10oC to 50oC and RH measurement range 0-90%RH, accuracy ±2 %RH with all other mounting accessories complete as required.
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
13BOQ25 mm thickness closed cell nitrile rubber200.00Sqmm1725.00345000.00
Supply and fixing of 25 mm thickness closed cell nitrile rubber (Class O) insulation on existing duct after applying 2 coats of cold setting adhesive (CPRX Compound). The joints shall be sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications.Thermal conductivity should not exceed 0.037W/mk
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
14BOQAcoustic insullation 10 mm30.00Sqmm95.002850.00

Subwork Name                                   Specification Number                        Quantity          UOM                   Rate(INR)      Amount(INR)

Supply, installtion, testing and commissioning of Acoustic insullation 10 mm thick open cell nitrile rubber 1 Sqft 95.00

 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
15BOQDUCTING & INSULATION WORKS2000.00Sqft120.00240000.00
DUCTING & INSULATION WORKS :Supply, Installation, Testing & Commissioning & Handing over of the following: Rectangular Aluminium ducting ? Factory Fabricated complete with splitter dampers, turning vanes, access doors, supports, air tight joints with dual insulation to avoid leakage, applied with sealant etc. as per drawings. The duct supporting shall be as per SMACNA standards.24 G
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
16BOQDUCTING & INSULATION WORKS2600.00Sqft145.00377000.00
DUCTING & INSULATION WORKS :Supply, Installation, Testing & Commissioning & Handing over of the following: Rectangular Aluminium ducting ? Factory Fabricated complete with splitter dampers, turning vanes, access doors, supports, air tight joints with dual insulation to avoid leakage, applied with sealant etc. as per drawings. The duct supporting shall be as per SMACNA standards.22 G
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
17BOQLaminar Flow Tent1.00No255000.00255000.00
Design, Fabrication, Supply, Installation, Testing & Commissioning of Laminar Flow Tent of size 8 ft x 6 ft, fabricated from SS 304 grade sheet, fitted with 6 Nos. HEPA filters (each approx. 2 ft x 2 ft), minimum 99.97% efficiency @ 0.3 micron, conforming to EN 1822 / ISO Class 5, with a stainless steel perforated bottom grill, and suspended above the table using SS supports and hangers.
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
18BOQVertical risers6.00No12756.0076536.00
Vertical risers with return & supply grills for AHU 1,2 & 3   
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
19BOQExpansion valve6.00No19795.00118770.00
SITC of Expansion valve along with necessary fixing arrangement & Filter dryer for sutable size for liquid line & capacity. AHU 1,2 & 3
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
20BOQRefrigerant65.00Kg2095.00136175.00
SITC of Refrigerant ECO Frendly. (410a / 407 or eqt).    
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
21BOQREFRIGERANT PIPES120.00Rmt1840.00220800.00

Subwork Name                                   Specification Number                        Quantity          UOM                   Rate(INR)      Amount(INR)

REFRIGERANT PIPES: – 18G. Hard drawn Refrigerant piping circuit with 19mm thick nitrile rubber tube insulation with polyshield covering suitable for outdoor installation.Providing 2 runs of Copper tubes for suction and liquid between indoor and outdoor unit for split/Casseete Air-Conditioner including

foaming etc.

 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
22BOQDX OUTDOOR UNITS2.00No345850.00691700.00
DX OUTDOOR UNITS: The DX type outdoor condensing unit, shall comprise adequately sized coils to meet the heat rejection requirements. The ODU shall be supplied with eco-friendly refrigerants like R410 A. The outdoor unit shall house scroll type compressors, thermostats, HP/LP cut-outs, condenser coil, filter drier, strainer, fan, fan motor, oil return kit, in-built electrical panel with necessary starter, relays, controls, etc., and the complete unit shall be suitable for outdoor application. The Outdoor Condensing unit heat rejection capacity shall be suitable for the DX coil installed in the AHU and the compressor load. The units shall be suitable for input power supply of 3 phase, 415 volts, 50 Hz. The DX outdoor unit shall be selected for 41 °C outdoor air entering temperature.MAKE:HITACHI/DAIKIN /Blue Star Nominal capacity compressors, condensing fans, necessary starter panel with control cabling, and other components as specified above suitable for the DX evaporator coil specified above OT’s.Towards supply of A/C Condensing unit, Dx type, Double circuit unit with double compressor copper condenser Capacity: 11 TR
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
23BOQDX OUTDOOR UNITS1.00No458850.00458850.00
DX OUTDOOR UNITS: The DX type outdoor condensing unit, shall comprise adequately sized coils to meet the heat rejection requirements. The ODU shall be supplied with eco-friendly refrigerants like R410 A. The outdoor unit shall house scroll type compressors, thermostats, HP/LP cut-outs, condenser coil, filter drier, strainer, fan, fan motor, oil return kit, in-built electrical panel with necessary starter, relays, controls, etc., and the complete unit shall be suitable for outdoor application. The Outdoor Condensing unit heat rejection capacity shall be suitable for the DX coil installed in the AHU and the compressor load. The units shall be suitable for input power supply of 3 phase, 415 volts, 50 Hz. The DX outdoor unit shall be selected for 41 °C outdoor air entering temperature.MAKE:HITACHI/DAIKIN /Blue Star Nominal capacity compressors, condensing fans, necessary starter panel with control cabling, and other components as specified above suitable for the DX evaporator coil specified above OT’s.Towards supply of A/C Condensing unit, Dx type, Double circuit unit with double compressor copper condenser Capacity: 17 TR AHU- 1
 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
  24  BOQDouble skin vertical floor mounted Thermal break AHU  2.00  No  461967.00  923934.00
Double skin vertical floor mounted Thermal break AHU consisting of supply air damper, etc complete with all accessories for the following capacity – Sections: Pre Filter (10mic-50mm tk), Coil and Fan section Insulation 25mm tk RPUF, Panel’s Inner 0.6 mm GI Plain and Outer Pre-painted 0.6 mm tk. Frame Aluminum extruded with nylon corners with Hollow Profile. with return air Plenum with VCD for return air & fresh air openings. Fan DIDW Revers curved make NICOTRA/KRUGER/EQVT Motor: 3PH-IE-2-, MAKE-CG/ABB/EQVT Cooling coil 1/2″-6 Row DX COIL. Aluminum finned copper tube with

Subwork Name                                  Specification Number                       Quantity          UOM                   Rate(INR)       Amount(INR)

SS Drain pan, Filters 10 mic HDPE media in GI Casing, Fine filters bag type, & HEPA filters. following capacities. Static 150mm.Capacity: 11 TR (2x 5.5 TR)

 Subwork NameSpecification NumberQuantityUOMRate(INR)Amount(INR)
  25  BOQDouble skin vertical floor mounted Thermal break AHU  1.00  No  502476.00  502476.00
Double skin vertical floor mounted Thermal break AHU consisting of supply air damper, etc complete with all accessories for the following capacity – Sections: Pre Filter (10mic-50mm tk), Coil and Fan section Insulation 25mm tk RPUF, Panel’s Inner 0.6 mm GI Plain and Outer Pre-painted 0.6 mm tk. Frame Aluminum extruded with nylon corners with Hollow Profile. with return air Plenum with VCD for return air & fresh air openings. Fan DIDW Revers curved make NICOTRA/KRUGER/EQVT Motor: 3PH-IE-2-, MAKE-CG/ABB/EQVT Cooling coil 1/2″-6 Row DX COIL. Aluminum finned copper tube with SS Drain pan, Filters 10 mic HDPE media in GI Casing, Fine filters bag type, & HEPA filters. following capacities. Static 150mm.Capacity: 16.5 TR AHU- 1 (11+5.5)

Total(INR): 5879983

Tenders

Post navigation

Previous post
Next post

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Latest

Hyderabad Kicks Off Major Ration Card Distribution, Benefiting Over 2.32 Lakh Residents
Top Stories 0

Hyderabad Kicks Off Major Ration Card Distribution, Benefiting Over 2.32 Lakh Residents

Ai Generated Article August 4, 2025
A.R. Rahman Returns to Hyderabad for “The Wonderment Tour” on November 8
Top Stories 0

A.R. Rahman Returns to Hyderabad for “The Wonderment Tour” on November 8

Ai Generated Article August 4, 2025
Top Stories 0

Ibrahim Khalil Road, Makkah: A Hub for Hyderabadi and South Asian Pilgrims

Ai Generated Article July 26, 2025
Uncategorized 0

Continuous Rains Bring Hyderabad Businesses to a Standstill

Ai Generated Article July 26, 2025
©2025 hyderabadupdates.com | WordPress Theme by SuperbThemes